50 for mini stonewold.
Redland 50 roof tile vents.
A range of discreet ventilating tiles suitable for both low and high level roof space ventilation to combat condensation as well as mechanical and soil pipe ventilation.
Width 330 mm.
Length 420 mm.
The roof tile vent has a simple structure to match standard roof tiles.
60 for concrete plain tiles heathland.
2014 code of practice for slating and tiling including shingles providing redland fixing recommendations are complied with.
Image for illustration purposes only tile cowl vent features.
The redland 50 double roman rapid roof vent tile is effective for roof space ventilation mechanical extraction and soil vent termination.
Sleek design ensures the vent is almost invisible from ground level.
Choose from over 8 brands of roof tile vents from the likes of marley klober and hambleside danelaw to reduce condensation in loft space and ensure an extended roof life span.
Suitable for roof space ventilation mechanical extraction and soil vent termination.
Cowl vent for redland 50 double roman roof tiles.
57 5 for rosemary clay tiles.
Adding roof ventilation can allow you to prevent rotting in timbers and building frames saving you from expensive repairs.
Cowl incorporates barriers to prevent water ingress and block wind driven rain allowing the water to drain away down slope.
Tiles will meet all the requirements of bs 5534.
The redvent eaves ventilation system is available in two pack sizes for rafter centres from 350 450mm and 450 600mm.
A restriction to two storeys applies to the plain tile rapid roof vent.
Redland 50 double roman.
Naturally this ideal befits the name because the clay of every two piece redland tile is truly of the earth.
Suitable for use with most popular interlocking concrete tiles and plain tiles.
From the heart of the land.
Historically clay tile was formed by hand.
Redland 50 double roman tiles have been rigorously tested in the group wind tunnel where combinations of high wind and driving rain are used to determine the tile performance with respect to wind loading and weathertightness.
As a result personality was always a part of the handmade process.
The vent is 32 inches wide 23 inches long and 2 inches high in the front tapering to blend in with the roof decking at the top.
No building height restriction applies to the new mini stonewold 50 double roman grovebury renown or redland 49 vents for soil vent termination.
The harcon corrovent low profile roof tile cowl vent to suit the redland 50 double roman roof tile offers an unobtrusive low or high level ventilation solution complete with a round integral felt sleeve.
60 for all profiled tiles.
Water entering the vent flows back out onto the roof.
This model is well constructed with external louvers on each side as well as internal water diverters and splash guards.
The effective ventilation area per metre of eaves is 14 600mm2.